Template · Heat pumps
Heat pump survey form: what to ask the homeowner before the visit
A heat pump survey goes wrong in a few predictable places: the only spot for the outdoor unit has no base, the plant room is too low for the cylinder, the landlord will not allow a hole through the wall, or the meter cupboard has no free space. A short form the homeowner fills in with photos shows you these points before anyone drives out.
Updated November 14, 2026What a pre-survey form can and cannot do
The form does not replace your survey, your heat loss calculation or the system design. It answers a narrower question: is there anything at this property that stops the job or needs another trade in before you? If there is, you know before anyone sets off.
Send it after the first enquiry and before you book the survey visit. If the survey is already done, send the same form before installation day to confirm nothing has changed since.
The pre-survey questions
Copy the table into your own form or email. The third column is the answer that should stop you booking the visit until it is sorted out. Not every question has one.
| Question to the homeowner | Ask for | Stops the job when |
|---|---|---|
| What heats the home today? | Gas, oil, electric or storage heaters, district heating, none (new build) | Not on its own; it tells you what has to come out |
| Where would the outdoor unit go? | A photo taken from a few steps back, showing the wall, the ground and any windows nearby | There is no spot the homeowner would accept |
| Is there a firm, level base there (concrete slab, plinth or wall brackets)? | Yes or no | No base and nobody has agreed to build one |
| How far is that spot from the nearest neighbouring window or the boundary? | In metres; a rough estimate is fine | The distance fails the noise check you run with the manufacturer’s data |
| Is there somewhere for the condensate to drain (gravel, gully, soakaway)? | Yes or no, and where | Water would run onto a path or a neighbour’s side |
| Where would the cylinder or indoor unit go (the plant room)? | A photo of the room showing free wall and floor space and the current boiler | There is no room for it |
| How high is the ceiling in the plant room? | Millimetres or inches, measured | Lower than the cylinder plus your clearance |
| Are we allowed to drill through the outside wall to run the pipes to that room? | Yes or no; tenants ask the landlord first | Drilling is not allowed |
| Can you open the meter cupboard and photograph it? | A photo with the door open so meters and fuses are visible | – |
| Is there free space in the meter cupboard for extra equipment, such as a second meter? | Yes, no or don’t know | No space: the electrics need an upgrade first |
| Has anyone notified the network operator (DNO) about the heat pump? | Yes, no or don’t know | Depends on your process; agree who notifies |
| How do we get the unit to the spot (parking, side gate, steps)? | A short note | No way through for the unit on its pallet |
Four photos that save a visit
- The outdoor spot from a distance. One step closer and you lose the window above it or the drain beside it.
- The plant room with the current boiler. It shows space, pipe positions and what has to be removed.
- The open meter cupboard. An electrician can judge free space from it before the visit.
- The wall where the pipes would pass. Ask for the outside and the inside of the same wall.
Ask for daylight photos and say how far to stand back. Homeowners send close-ups unless the form tells them otherwise.
PDF, web form or a link with checks
A PDF is quick to make and slow to come back: the homeowner prints it, photographs it and sends the photos in a separate email. A web form is better, but someone in the office still reads every answer and decides whether the visit can go ahead. Answers that should stop the job look like any other answer in the inbox.
Whichever you use, keep the same questions for every job, so the person who books the visit knows where to look and what counts as a blocker.
The same form as an InstallCue link
InstallCue ships a heat pump starter template with these questions. You send the homeowner a link; it opens straight in their phone’s browser, in their language, with nothing to install. These answers become blockers as soon as they are given:
- no firm, level surface for the outdoor unit,
- a plant room ceiling under 1,900 mm (the starter value; set it to suit your cylinder),
- no permission for the wall opening or core drilling,
- no free space in the meter cupboard.
The template asks for three photos (outdoor spot, plant room, open meter cupboard) and records the homeowner’s confirmation that the measurements were taken on site; add the wall photo in your own copy. The condensate question is a note in the starter template; make it a blocker in your own copy if you need to. Until the homeowner submits the form, InstallCue sends up to two email reminders, provided their email address is on file. A person on your team marks the site Ready; then you send the crew the answers and photos as an install pack link.
Prices as of 14 November 2026: Starter £250, $250 or €250 a month (net), up to 250 site checks; no setup fee; cancellable monthly. See all plans and prices.
Where the form stops
- It does not calculate heat loss or size the heat pump; use your design software for that.
- Homeowner measurements are estimates; your survey or your crew confirms the critical ones.
- It does not replace any visit that a scheme, a grant or your certification requires.
For the general list of what to confirm before any installation, see the pre-installation site readiness checklist.
Questions installers ask
- Can I change the questions?
- Yes. The starter template is a copy in your workspace; you can change the questions, photos and values that trigger a blocker.
- Does the homeowner need to register?
- No. The link is enough, and it expires after the time you choose.
- Does it work for air conditioning, solar or EV chargers?
- Yes. There are also starter templates for split-system air conditioning, solar PV with battery storage and EV chargers.
See how InstallCue checks site readiness · Plans and prices